Appliance Repair Royal Arkansas

ApplianceCare Rated out of 5 stars based on 0 customer reviews

We serviced a
WHIRLPOOL DISHWASHER
Model WDT750SAKZ0
Near Royal, AR 71968
Blake D.
Job Details: 08/04/2022
"Replaced heating element due to sp, tested unit no leaks and heat comes on unit operation checks okay ; dspstn on spec-tagged invntry: 1 W11537778 HEATER"
We serviced a
MAYTAG WASHER
Model MVWX655DW1
Near Royal, AR 71968
Blake D.
Job Details: 04/21/2022
"Inspected unit for not working, ran diagnostic found f7e5 error test 3A pg 13 test 6 found to be out of range went to step 13, checked to make sure connections werent lose found none to be loose, step 16 replace actuator W10913953 ($63.18) labor ($72.45) and sc($109.00) customer does not want to move forward only paid sc ($120.17) using check ending in 1017"
We serviced a
MAYTAG WASHER
Model MVWB835DW4
Near Royal, AR 71968
Blake D.
Job Details: 04/21/2022
"Inspected unit for not spinning properly, ran diagnostic found error code f7e9 rotor lock up, when trying to spin the basket I found it to be stiff instead of smooth, removed rotor and took the slider out, found the slider to be damaged, diagnosed to need slider W10734521 ($28.22) labor ($72.45) and sc ($109.00) customer is paying sc ($120.17) using check ending in 2268, customer will pay part and labor on return; ordrng 1 W10734521 (Slider)"
We serviced a
WHIRLPOOL KITCHEN
Model KUIX535HPS
Near Royal, AR 71968
Blake D.
Job Details: 04/07/2022
"Tried calling twice no answer, arrived at Address, customer here informed me they didnt call anything in"
We serviced a
MAYTAG WASHER
Model MVW7230HW0
Near Royal, AR 71968
Blake D.
Job Details: 03/28/2022
"Inspected unit for off balance, customer explained to me that when they wash king sheets and pillow cases the unit gets off balance, I informed the customer that cleaning king and queen size needs to be separate loads, all together is to much for this unit and will cause it to go off balance, ran diagnostic found error code f0e5, tested the suspension doesnt bounce more than once checked okay, ran auto test and calibration, unit passed both test no error codes unit runs as designed"